Zum Inhalt springen
VISCOUNTQuality Certifications

Guidance

After Stage 2: how the certification decision is taken

Your audit ends in a recommendation. A reviewer who did not audit you takes the decision, and major nonconformities must be verified before it can be made.

Veröffentlicht am

Diesen Beitrag teilen

Your organization becomes certified on the day the certification decision is taken. The closing meeting of a Stage 2 audit ends in a recommendation from the audit team. Under clause 9.5 of ISO/IEC 17021-1, the decision is taken by people who took no part in auditing you, and before they take it they review three things: whether the audit evidence is sufficient for the scope you applied for, whether every major nonconformity has a correction and corrective action that we have verified, and whether every minor nonconformity has a plan we have reviewed and accepted. When the decision can be taken, and what scope it covers, depends on those three reviews.

What the reviewer works from

The reviewer reads the audit record: the audit plan, the report, each finding with the evidence it rests on, and your responses. They can ask the audit team to clarify something in the record. They do not revisit your site or interview your staff. Anything an auditor saw on the day that never reached the report is unavailable to the decision, which is one reason our findings are issued in writing with their evidence attached.

The sufficiency review is measured against the scope in the proposal you agreed, meaning its activities and its sites. The decision can cover only what the evidence covers. Where a site named on the audit plan was not visited, or an activity in the requested scope was not running during the audit and could not be seen in operation, the recommendation alone cannot carry that part of the scope. The outcome is either a narrower scope on the certificate or further audit activity before the decision. A site or process that is on the plan and unavailable on the day leaves a gap that nobody can fill afterward from memory.

Major and minor nonconformities

The grade of a finding decides the timing. For a minor nonconformity, the reviewer needs a plan for correction and corrective action that we have reviewed and accepted. The decision can then proceed, and implementation is verified at the first surveillance audit. For a major nonconformity, the correction and corrective action have to be implemented and verified before the decision is taken. Depending on what the finding concerns, verification can rest on records you send us or may need a further visit. A Stage 2 that ends with one major nonconformity does not end in a certificate until the work is done and we have seen the evidence.

The response that stalls a decision is a major nonconformity answered with a plan. "The procedure will be revised by the end of the month and training will follow" is an acceptable answer to a minor finding. Against a major one it leaves nothing to verify, so the decision waits until the revised procedure exists and the training records do too. The cause analysis matters in the same way. A response that stops at the correction gives the reviewer no basis for concluding the nonconformity will not recur, and a reviewer who reaches that conclusion sends the response back.

The second failure mode happens outside the audit. An organization leaves the closing meeting with a positive recommendation and describes itself as certified in a tender submitted that week. Until the decision is taken there is no certificate number and no entry in our public register, so a buyer who checks finds nothing, and the bidder has made a claim that the issuing body's own records contradict. The accurate wording in the interval is that Stage 2 is complete and the certification decision is pending. Accreditation marks follow the same rule, because a mark refers to a certificate and there is no certificate yet.

What the decision is independent of

The separation between the audit team and the decision is a requirement of the standard our certification activity is accredited to, and EIAC and ANAB assess whether we apply it. It runs in both directions. A lead auditor cannot promise you a certificate at the closing meeting, and nobody else in our organization can promise one either, because the person who decides has to be free to disagree with the recommendation. The reviewer is also independent of the commercial relationship, so a deadline set by your client's tender is a fact about your schedule and has no bearing on the record.

Once the decision is taken, the scope wording, the accreditation marks and the validity dates on the certificate are confirmed against it, and the certificate is issued and published in the register. The register therefore shows what was decided: the standard edition, the scope, the sites, the status and the dates. Recertification at the end of the three-year cycle ends in a new decision under the same rule, and that decision has to be taken before the existing certificate expires.

If you disagree with a decision we have taken about your certification, the route is an appeal, and it is reviewed by people who took no part in the decision being challenged. How to lodge one is set out on our complaints and appeals page.

Diesen Beitrag teilen